EX02-SLPR25

current output.EX02-SLPR50 operates from 90–264Vac with
different rated output voltages ranging between 24V and 54Vdc.
Thanks to the high efficiency up to 89%, with the fanless design,
the entire series can operate at -40℃~+70℃ case temperature
under free air convection. The entire series is rated at lP66 ingress
protection level and is suitable for a variety of applications at dry,
damp or wet locations.

Key words:

数据1 数据2 数据3 数据4
EX02-SLPR25
+
  • EX02-SLPR25
 
Features
  • Constant Current mode output
  • Plastic housing with Class ll design
  • lP66 rating for indoor or outdoor installations
  • Typical lifetime>50000 hours
  • 5 years warranty

Standard Specification

MODELEX02-SLPR50-54MEX02-SLPR50-42M
INPUTVoltage  Range100 ~ 240Vac  (90-264Vac)100 ~ 240Vac  (90-264Vac)
140 ~ 250Vdc 140 ~ 250Vdc 
Frequency Range50/60Hz(47~63Hz)       50/60Hz(47~63Hz)       
Power Efficiency89.0%@120Vac full load88.0%@120Vac full load
90.0%@230Vac full load89.0%@230Vac full load
Power Factor>0.9@120Vac/60Hz(15-100 %) full load>0.9@120Vac/60Hz(15-100 %) full load
>0.9@230Vac/50Hz(60-100 %) full load>0.9@230Vac/50Hz(60-100 %) full load
Total Harmonic Distortion<20%@120Vac(30-100 %) full load<20%@120Vac(30-100 %) full load
<20%@230Vac(60-100 %) full load<20%@230Vac(60-100 %) full load
AC Current(max)                   0.55A@120Vac full load0.55A@120Vac full load
0.26A@230Vac full load0.26A@230Vac full load
Standby power<1W<1W
Inrush Current                (cold engine start)max120Vac 20A peak,500us duration(10% Ipeak)120Vac 20A peak,500us duration(10% Ipeak)
230Vac 28A peak,600us duration(10% Ipeak)230Vac 28A peak,600us duration(10% Ipeak)
Leakage current(max)<0.5mA@230Vac<0.5mA@230Vac
MODELEX02-SLPR50-54MEX02-SLPR50-42M
OutputCurrent(mA)/Voltage (VDC) Power(W)24-54Vdc/1000mA/50W24-42Vdc/1050mA/50W
Current ripple<5%<5%
ChannelSingle channelSingle channel
Linear Regulation±5%±5%
No-load output voltage<60Vdc<48Vdc
Start Time<0.5S@230Vac   <1S@120Vac<0.5S@230Vac   <1S@120Vac
ProtectionOver TemperatureWhen temperature is too high,shut down the output, return to normal after release
Over loadThe on-load voltage is too high to enter the protection. return to normal after release
Short CircuitEnter hiccup mode and return to normal after release
Safety standardIEC60079-0、IEC60079-18
EMCCompliance to BS EN/EN55015
Operating Temperature-40~+70℃
Storage Temperature,Humidity-40°C to 85°C,10-95%RH
Warranty Tc50000Hour (s)@TC:<75℃
Surge protectionL-N 6KV   
IP RatingIP66
Weight (g) 
NoteAs a part of the terminal equipment system, the LED driver must be combined with the whole lamp system for EMC final confirmation.
Electrical Curve Diagram

Dimension Diagram

Product Wiring:One side is the AC input terminal, and the other side is the DC output terminal. The 18# brown/blue wires are connected to AC/L and AC/N respectively, while the 18# red/black wires are connected to the positive and negative terminals of the LED light accordingly.

Product Lable
Ordering Information
List of SKU Naming: EX02-SLPR50
SeriesNumber of OutputsWide Input VoltageDrive AppearanceOutput PowerOutput VoltageDimming Function
EX02-S = Single channelLPR = AC100~240V (DC140~250V)No = Drive is square50 = 50W-54 = 54VM = Multiple Control Functions
      No = NO Additional Function
 

Previous Page

Next page

Previous Page

Next page

Related Products

undefined

undefined

Message

*Leave your contact information to get a free product quote

SAFER-Ex